← All articles

Blog

ESD Testing of Cleanroom Garments in Indonesia: What Results Mean

How Indonesian cleanroom laundries and their CPOB, medical-device and electronics customers should read ESD garment test results, and what to record.

6 min read
  • mid
  • laundry-qc
  • indonesia

An ESD test result on a cleanroom garment tells you how that garment, in that condition, behaved under a specific method on a specific day. It does not tell you the garment is “ESD safe” for ever. For an Indonesian cleanroom laundry, the useful question is not “did it pass?” but “what was measured, against which limit, after how many wash cycles, and can I show the record?”

The short answer

  • ESD results describe static-control behaviour (usually electrical resistance or charge decay of the fabric and its conductive yarn) at the time of testing.
  • Washing, drying and sterilisation can change that behaviour over a garment’s life, so one passing result at purchase is not enough.
  • The pass/fail limit comes from the customer specification and the standard it cites, not from the laundry. Where the standard is paywalled, read the current edition rather than relying on summaries, including this one.
  • The result is only as good as the record: garment ID, batch, method, conditions, instrument, operator, reviewer.

Why ESD matters in some Indonesian cleanrooms and not others

ESD control is a core concern in electronics and semiconductor assembly, where a static discharge can damage components. Indonesia has electronics and component manufacturing clusters, notably around Batam and the Greater Jakarta industrial belt, and those sites often specify ESD garments.

In pharmaceutical (CPOB), cosmetics and food cleanrooms, the main garment concerns are particles, fibre shedding and microbiological control. ESD can still matter there, for example near powders or flammable solvents, or in medical-device assembly with electronic parts, but it is usually a secondary requirement. Know which of your customers care, because it changes how much testing you do and how you report it.

What is actually being tested

Garments for static control typically contain a conductive grid or stripe woven into the fabric. Laboratories commonly look at two kinds of property:

  1. Resistance of the fabric, or between points on the garment, measured with electrodes on a controlled-humidity sample.
  2. Charge decay or shielding behaviour, which describes how quickly a charged fabric dissipates its charge.

The exact methods, electrode geometry, humidity conditioning and limits are defined in standards you need to buy and read. The ESD Association standards page lists the ANSI/ESD documents, including ANSI/ESD S20.20 (the ESD control programme standard) and ANSI/ESD STM2.1-2018, which ESDA lists among its endorsed standards. That page does not describe the garment test scope in detail, so confirm the exact method your customer cites. IEC publishes a parallel 61340 series on electrostatics; again, check the edition your customer names in their specification.

IEST-RP-CC003 is the recommended practice for cleanroom garment systems. According to IEST, it gives non-mandatory guidance on selecting, specifying, maintaining and testing garments, covers garment tracking such as barcodes and RFID for service life, and includes appendices on test recommendations for contamination control. It is a guidance document, not a regulation, and the contamination tests it discusses are separate from ESD testing.

How to read a result

Do not read a single number in isolation. Ask these questions:

QuestionWhy it matters
Which method and edition?Different methods give different numbers for the same fabric.
What humidity and temperature?Resistance of textiles is sensitive to moisture.
New, or after how many wash cycles?Conductive yarn and finishes can degrade.
Which garment, which batch?A result for one lot says little about the next.
What limit applied, and who set it?The customer specification normally decides.
Was the instrument in calibration?An uncalibrated meter makes the result unreliable.

A result near the limit deserves more attention than a comfortable pass. Trending several results over a garment’s life is more informative than any one measurement.

Common mistakes in laundry ESD programmes

  • Testing only new garments. The risk usually grows with washing, not at the first use.
  • No humidity record. Without conditions, a result cannot be compared with last month’s.
  • Mixing garment types. Smocks, coveralls and hoods may be tested differently; keep them separate in records.
  • Treating a pass as a certificate for the whole lot. Sampling plans should be agreed with the customer and written down.
  • Results on paper or in a spreadsheet that cannot show who changed what. That is a weak point in any audit.

The CPOB and customer-audit angle

For pharmaceutical customers, BPOM regulates under CPOB (Cara Pembuatan Obat yang Baik), Indonesia’s GMP framework. BPOM is listed by PIC/S as a participating authority, with accession in July 2012, which is why CPOB inspections are read against international GMP expectations. This article does not quote CPOB clauses; check the current CPOB on BPOM’s regulation portal.

In practice, your customer’s quality unit will ask how you control the garment service, not just whether a test passed. Expect questions about:

  • Traceability from garment to wash batch to test result.
  • Defined review and release by someone other than the person who ran the test.
  • Calibration and maintenance of the test equipment.
  • Handling of out-of-specification results, including what happens to the batch.
  • Retention of records and their integrity (who entered, who changed, when).

Electronics customers, often auditing against an ESD control programme such as ANSI/ESD S20.20, will ask similar things in a different vocabulary: periodic verification, records, and evidence that garments in use still meet the requirement.

Practical cost thinking in rupiah

We will not quote prices, because they vary by instrument, supplier and volume. But the cost structure is worth thinking through before you add ESD testing:

  • Resistance test equipment and electrodes, plus periodic calibration.
  • A conditioning space or procedure for humidity control.
  • Technician time per sample, multiplied by sampling frequency.
  • The cost of a rejected batch: rewash, delay to the customer, possible replacement garments.

Compare those against what your ESD-specifying customers pay for the service. If ESD testing is a small share of your volume, a tightly scoped sampling plan agreed with the customer is often more sensible than testing everything.

A workable minimum

  1. Get the customer’s ESD specification in writing, with the standard and edition named.
  2. Write a short procedure covering conditioning, method, sample size and limits.
  3. Test at agreed points in the garment’s wash life, not only when new.
  4. Record garment ID, batch, conditions, instrument ID, result, operator and reviewer.
  5. Review results as a trend, and define what triggers an investigation.
  6. Keep calibration certificates with the data.

Software can help with the record-keeping, but it supports your quality system; it does not make anyone compliant. Responsibility for release decisions stays with your quality unit.

Talk it through

If you are working out how to record and trend ESD, particle and other garment test results with proper review and an audit trail, we are happy to have a no-charge conversation about it. Our laundry quality control system is one option we can discuss, alongside simply tightening what you already do. Get in touch with Teknologia Solutions.


Sources: ESD Association standards page; IEST-RP-CC003 page; PIC/S members; BPOM. Standards such as ANSI/ESD and IEC 61340 are paywalled and this article does not reproduce their limits or methods. Verify everything against the primary sources and the current edition of each standard and regulation before relying on it.