← All articles

Blog

ESD Testing of Cleanroom Garments in Malaysia: What Results Mean

How Malaysian cleanroom laundries and their electronics and pharma customers should read ESD garment test results, and what to record for each batch.

6 min read
  • mid
  • laundry-qc
  • malaysia

The short answer

An ESD test result on a cleanroom garment tells you how the fabric conducts or dissipates charge, measured as electrical resistance under a defined method. A pass means the garment met the limit of the specification your customer named. It does not mean the garment is “ESD safe” in every situation, and it says nothing by itself about particles or sterility.

For a Malaysian laundry, the practical point is this: ESD results matter most to your electronics and semiconductor customers, but the same garments often serve pharmaceutical and medical-device cleanrooms too. So the record you keep has to stand up to two different kinds of audit.

Why ESD matters in Malaysia specifically

Malaysia’s electrical and electronics sector is large, and the government has published a National Semiconductor Strategy aimed at moving the industry up the value chain, from assembly and test toward design and advanced packaging. Customers moving in that direction tend to tighten their supplier requirements, including garment handling.

Static-sensitive components are damaged by discharge that operators often cannot feel. Garments are one of several controls (wrist straps, flooring, footwear, ionisation), so a customer’s ESD programme will usually ask the laundry for evidence that laundering has not degraded the garment’s static-control properties.

Which standards sit behind the numbers

Public sources describe the picture like this:

  • ANSI/ESD STM2.1 is a test method for garment resistance. The ESD Association lists IEC 61340-4-9 as technically equivalent. A vendor explainer describes two measurements: point-to-point resistance and point-to-groundable-point resistance.
  • ANSI/ESD S20.20 (and the related IEC 61340-5-1) are the programme standards that set the requirements garments are judged against. The test method measures; the programme standard and your customer’s specification decide what is acceptable.

These standards are paywalled. The summaries above come from public pages, so read the exact limits and conditions in the current edition before you write them into a procedure.

Reading the result: three garment categories

The vendor explainer above says garments must fall into one of three categories to be considered compliant with S20.20, and gives a minimum point-to-point requirement of below 1.0 x 10^11 ohms. In practice the three groups look like this:

CategoryWhat is measuredLimit
Static control garmentPoint-to-point resistanceBelow 1.0 x 10^11 ohms (minimum requirement per the vendor explainer)
Groundable garmentPoint-to-point and point-to-groundable-pointTake the limit from the current S20.20 edition
Groundable garment systemAdds the body-contact-to-ground pathTake the limit from the current S20.20 edition

Treat the table as orientation only. The one figure shown comes from a vendor page, not the standard itself. Your customer’s specification, which names the standard and edition, is the authority.

The category matters more than the number. A static control garment is not intended to be grounded; a groundable one is only effective if the operator actually connects it. A lab report that shows a good number for the wrong category is a misleading report.

What the results do not tell you

  • Particle shedding. A garment can pass ESD and still shed. Particle testing is a separate result and should be a separate line on the certificate.
  • Performance after many washes. Conductive fibres or treatments can change with laundering. STM2.1 is described in public sources as requiring garments to be cleaned at least three times before testing, which shows the method expects laundered garments, but it does not tell you the result after cycle fifty. That is why trend data per garment lot is worth keeping.
  • Humidity effects. Resistance depends on test conditions. Record temperature and relative humidity, because Malaysian ambient humidity is high and your test room may not match the customer’s. Check the standard for the required conditioning.
  • Whole-system protection. Garments alone do not make a person safe for static-sensitive work.

How this reads to a pharmaceutical or device auditor

ESD is rarely a GMP topic by itself, but the way you handle the record is. Malaysia’s pharmaceutical regulator, NPRA, publishes a page on its recognition and PIC/S membership, and pharmaceutical GMP inspections in Malaysia follow PIC/S-aligned GMP expectations. Confirm the current guide version with NPRA. An auditor from a pharmaceutical customer will therefore expect documented, traceable, reviewed results for any test you perform on garments for their cleanrooms, whether or not ESD is among them.

For medical devices, Malaysia’s Medical Device Authority (MDA) regime includes Good Distribution Practice for Medical Devices (GDPMD) for supply-chain parties. Whether it applies to a laundry depends on the customer’s role and the official MDA guideline, so ask the customer and check MDA rather than assume.

Software and procedures support these obligations. Responsibility for compliance stays with your quality unit and your customer.

A practical record for each batch

Whatever the customer’s standard, a defensible ESD record usually includes:

  1. Batch and garment lot identification, linked to the wash and dry records.
  2. Standard and edition used, and the garment category tested.
  3. Instrument identity and calibration status.
  4. Temperature, humidity and conditioning time.
  5. Individual readings, not just pass or fail.
  6. Who tested, who reviewed, and when. The reviewer should not be the tester.
  7. Disposition: release, hold or rewash, with a reason if the result was out of limit.

Typical findings in audits are not exotic. They are an uncalibrated meter, readings in a notebook that never reached the certificate, or an out-of-limit result that was retested until it passed without a recorded reason. Keep the original result and the retest, and record why.

Trend, do not just pass and fail

If a garment lot reads near the limit after each cycle, you have an early warning. Plot readings per lot against wash count. A slow drift lets you retire garments or change a process before a customer rejects a delivery. This is cheaper in ringgit terms than a rejected lot, a re-supply and a corrective-action report, though the actual cost depends on your contracts.

Questions to ask your customer

  • Which standard and edition, and which garment category?
  • What humidity and conditioning do they expect?
  • Do they want readings on the certificate or only pass or fail?
  • How many cycles should garments survive, and how will end of life be decided?

If a customer cannot answer, write down the assumption you used and get it confirmed.

Next step

If your ESD, particle and release records live in spreadsheets and paper, a conversation about how to link them is a reasonable start. Teknologia Solutions offers a no-charge conversation about your quality workflow, and our laundry quality control system is one option we can discuss if it fits. No obligation.


Sources: NPRA on PIC/S; MIDA on the National Semiconductor Strategy; ESDA on IEC 61340-4-9; Transforming Technologies, STM2.1 explained. Figures come from a vendor page because the standards are paywalled; verify against the current edition of each standard and the primary regulator documents.