Particle Count Testing for Cleanroom Garments in Indonesia: Helmke Drum and ASTM Explained

A plain-language guide for Indonesian cleanroom laundries and their CPOB customers on Helmke drum and ASTM-based particle count testing of garments.

5 min read
  • mid
  • laundry-qc
  • indonesia

Short answer: particle count testing for cleanroom garments measures how many particles a garment sheds when it is agitated, so a laundry can show that processed garments are clean enough for the room they will enter. The Helmke drum is the best-known way to do this. For Indonesian laundries serving pharmaceutical (CPOB), medical-device, cosmetics, food and electronics customers, the practical questions are less about the drum itself and more about which method the customer expects, what limit applies, and whether the result can be traced to a batch.

Why Indonesian customers ask for it

Garments are a main route by which people shed particles into a cleanroom. A garment that was laundered badly, or has reached the end of its service life, can release more fibres and particles than it should.

Indonesia’s drug and food regulator, BPOM, is a participating authority of the PIC/S inspection scheme, listed there since July 2012. In practice this means pharmaceutical manufacturers working to CPOB (Cara Pembuatan Obat yang Baik, Indonesia’s GMP) are inspected against a framework that expects documented contamination control, including gowning. BPOM publishes its current regulations, including CPOB-related ones, on its JDIH legal portal. Check there for the version in force before you quote a regulation number to a customer.

Your customer’s quality unit, not you, decides what is acceptable for their cleanroom grade. The laundry’s job is to test consistently, document it, and release only what meets the agreed specification.

What the Helmke drum is

The Helmke drum is a rotating drum in which a garment is tumbled while an airborne particle counter samples the air inside. Particles released by the fabric are counted by size range over a set time. The idea is simple: agitate the garment in a controlled way and measure what comes off.

I could not find a free public page that fully defines the procedure, so I will not quote drum speed, sample time, size channels or pass limits. Those details sit in the published method documents and, more importantly, in your customer’s specification.

Where ASTM and IEST fit

Several bodies publish related guidance, and the terminology is often mixed up in customer requests.

SourceWhat it isWhat to check
IEST-RP-CC003Non-mandatory guidance on selecting, specifying, maintaining and testing cleanroom garments, with a testing appendix and a quality control plan angleWhich edition (the public page lists CC003.5, March 2023)
ASTM methodsASTM publishes test methods used in textile and cleanroom contextsThe exact method number and year the customer cites; I could not verify specific numbers from open pages
ISO 14644 seriesCleanroom classification and related partsThe cleanroom class the garment is for

The practical point: when a customer says “ASTM-based”, ask which document, which edition, and whether they have a limit expressed per garment, per size range, or per cubic foot or litre. Different bases give numbers that cannot be compared directly.

Making the test meaningful

A particle count is only useful if it is repeatable. These are the habits that matter day to day:

  • Fix the method. Use one written procedure, one counter model, one set of size channels, and record them with every result.
  • Control the background. Record the empty-drum count before testing. A noisy background makes results unreliable.
  • Sample consistently. Decide how many garments per lot and which ones, and write it down.
  • Calibrate and maintain. Keep counter calibration records current and attach them to the results.
  • Link results to batch and wash cycle. A result without a lot number, wash programme and garment count is difficult to defend in an audit.

Examples by customer type

Pharmaceutical (CPOB). Expect the customer’s quality unit to audit you, ask for certificates per batch and want to see deviation handling. A failed count should lead to a documented re-wash or rejection, not a quiet retest.

Medical devices. Requirements often follow the customer’s quality system and the cleanroom class of the assembly area. Ask which class and which test standard they reference.

Cosmetics and food. Specifications may be less formal. Even so, a consistent particle test and written release record help when a buyer or auditor asks how clean garments are controlled.

Electronics and semiconductor. These customers often care about particles together with static (ESD) behaviour. Treat the two as separate tests with separate records.

Costs in rupiah

Equipment and testing costs vary widely by supplier and import duties, so I will not quote figures. When planning, list the real cost items: the particle counter and drum setup, calibration, operator time per batch, consumables, and re-wash cost for failed lots. Compare those to the cost of a rejected customer shipment. That comparison, in Rp, is the business case.

Individual results pass or fail. Over weeks they also show drift. A slow rise in counts can point to worn garments, a filter issue, or a change in the drying step before any single lot fails. Keeping results in a form you can chart makes this possible. Paper logs and scattered spreadsheets make it hard.

What software can and cannot do

Software can hold results against batches, enforce who reviews and releases, keep an audit trail and produce certificates. It cannot make your process compliant. Responsibility for GMP stays with the quality unit of the laundry and its customer, and any system used in a regulated setting needs its own validation effort.

Next step

If you are weighing how to record and release particle count results more reliably, we are happy to talk it through. Teknologia Solutions offers a no-charge conversation about our laundry quality control system and whether it suits your laundry. There is no obligation.


Sources: PIC/S members; BPOM; BPOM JDIH regulations; IEST-RP-CC003. Details of the Helmke drum procedure and specific ASTM method numbers could not be verified from open sources and are deliberately not stated. Always verify against primary sources, the current edition of each standard and your customer’s specification.