Particle Count Testing for Cleanroom Garments in Singapore

Helmke drum and ASTM particle tests for cleanroom garments, explained simply for Singapore laundries serving pharma, medtech and semiconductor customers.

6 min read
  • mid
  • laundry-qc
  • singapore

The short answer

Cleanroom garment particle testing is really two different questions. The Helmke drum asks how many particles a garment sheds when it is tumbled, which is a dynamic, airborne test. ASTM F51 asks how many particles are sitting on or in the fabric, which is a static, microscope-based test. A Singapore laundry that serves both a wafer fab and a sterile fill-finish line will usually be asked about one or both, and the customer’s contamination control strategy decides which.

Neither test makes a garment “compliant” by itself. They produce evidence. What you do with that evidence, and how you record it, is where audits are won or lost.

Why this matters in Singapore

Singapore’s cleanroom customer base is unusually mixed. Pharmaceutical and biologics manufacturers, medical device makers and semiconductor fabs all operate in Singapore, and a single laundry may serve several of them.

Their expectations differ:

  • Pharmaceutical manufacturers are licensed by the Health Sciences Authority (HSA). HSA’s GMP and GDP standards page points to the PIC/S GMP Guide as its GMP standard for manufacturers. The guide’s Annex 1 covers sterile medicinal products (the revised version took effect for sterile manufacturers on 25 August 2023), and garments are part of the contamination picture.
  • Medical device manufacturers must establish and maintain a quality management system conforming to ISO 13485, as stated on HSA’s medical device QMS page. Their supplier controls then flow down to a laundry that processes their gowning.
  • Semiconductor and electronics customers are less driven by a health regulator and more by their own internal specifications and by industry practice such as IEST recommended practices.

The practical consequence: your customer, not HSA, will usually tell you which test and which limits apply. HSA inspects the manufacturer, and the manufacturer audits you.

The Helmke drum, simply

The Helmke drum test is described in the IEST recommended practice on garment systems, IEST-RP-CC003. Trade coverage of IEST-RP-CC003.4 describes it as non-mandatory guidance covering selection, specification, maintenance and testing of garments.

In outline, as described in industry coverage:

  1. A garment is placed in a rotating drum.
  2. The drum tumbles it under dry conditions with mechanical agitation.
  3. A particle counter samples the air inside the drum while it turns.
  4. Counts are recorded and reported as an emission rate.

A second Semiconductor Digest piece on how the practice evolved notes that the revised test measures 0.3 and 0.5 micron particles and reports results as an emission rate, and warns that some drum setups sold by equipment vendors do not match the standard. That is worth taking seriously: if your drum geometry, airflow, counter or run time differs from what the recommended practice describes, your numbers are not comparable with anyone else’s.

I am describing the method from public summaries only. The exact procedure, any garment cleanliness categories and the current edition are defined in the IEST document itself, which is paywalled. Buy the current edition before you write a procedure around it.

ASTM F51, simply

ASTM F51/F51M is a test method for sizing and counting particulate contaminant in and on cleanroom garments. Per the ASTM abstract:

  • It targets detachable particles of 5 micron and larger, in and on the fabric.
  • It uses optical microscopy, with a size distribution and a surface obscuration analysis.
  • It is aimed at porous fabrics, not nonporous materials.
  • It is nondestructive and can be used on new, newly cleaned or worn garments, provided the sampled areas are representative.

The older F51-00 edition is now marked historical and the current edition is F51/F51M-20, so confirm which edition your customer cites.

How the two tests differ

Helmke drumASTM F51
QuestionWhat does the garment shed when moved?What particles are on or in the fabric?
MeasurementAirborne particle counterOptical microscope
Typical particle sizes0.3 and 0.5 micron (per the revised practice)5 micron and larger
Best atShowing real shedding behaviourShowing fibre and particle load on the fabric
Main riskNon-standard drum set-upsSampling unrepresentative areas

Many customers ask for one and ignore the other. If yours does, ask why, and write the answer down.

Where cleanroom classification fits

Garment tests are not the same as room classification. ISO 14644-1 classifies air cleanliness by airborne particle concentration. Customers use it to describe their rooms, and then ask whether your garments are suitable for that room. A Helmke drum result is evidence supporting that suitability argument. It is not a room classification.

Common failure points in the lab

Laundry labs commonly struggle in the same few places, none of them exotic:

  • Drum set-up not documented. Counter model, calibration date, flow rate and run time should be on every record.
  • Background not captured. An empty-drum count before each run is the only way to show the result is the garment and not the room.
  • Sampling plan not written. Which garments, how many per batch, and why that number.
  • Humidity and handling ignored. Singapore’s climate is humid year-round. Conditioning and storage before testing should be defined, not improvised.
  • Results in spreadsheets. Edited cells, overwritten files and no record of who reviewed what.

Records that survive an audit

Whoever audits you, the questions are similar. Can you link this result to this garment batch, wash cycle and operator? Who reviewed it, and could they have approved their own work? What changed between this result and the last one? Was a failing result investigated or quietly retested?

A defensible record usually includes:

  • Batch and garment identification
  • Method, edition and instrument identification
  • Raw counts and the calculation, not just pass or fail
  • Reviewer, approver and timestamps
  • A history of changes
  • The certificate or release record sent to the customer

Trending also matters. A laundry that sees emission rates creeping up over several months can act before a customer’s incoming check does. Cost of a rejected lot is usually counted in the customer’s S$ and in lost trust, not in your retest time.

A practical starting checklist

  1. Ask each customer which methods, editions and limits they require, in writing.
  2. Lock your drum and counter configuration to the cited method.
  3. Capture background counts every time.
  4. Write the sampling plan and the out-of-limit procedure.
  5. Separate who tests from who approves.
  6. Move results out of loose spreadsheets into a controlled record.

Software can help with step 6 and with traceability, review and trending, but it supports your quality unit’s decisions. It does not replace them, and no tool makes a laundry GMP compliant or validated on its own.

Talk to us

If you are working out how to structure particle test records, review steps and certificates, Teknologia Solutions is happy to talk it through. We offer a no-charge conversation about how our laundry quality control system could fit your process, with no obligation.


Sources: HSA, GMP and GDP standards; HSA, QMS for medical devices; Cleanroom Technology on IEST-RP-CC003.4; Semiconductor Digest on garment testing; Semiconductor Digest on IEST practice evolution; ASTM F51/F51M; ISO 14644-1:2015. Several standards are paywalled and some details above come from secondary summaries. Verify everything against the primary sources, the current editions of the standards, and your customers’ own requirements.