← All articles

Blog

Cleanroom Laundry Quality Control in Indonesia: What Gets Tested

What an Indonesian cleanroom laundry should test before releasing garments to CPOB pharma, device and electronics customers, and why each check matters.

5 min read
  • top
  • laundry-qc
  • indonesia

Short answer: a cleanroom laundry in Indonesia typically tests four things on every processed batch: particle shedding, electrostatic (ESD) behaviour where the customer needs it, moisture, and microbial or sterility-related status for aseptic work. Just as important, it keeps a record linking each result to a batch, an operator, a reviewer and a release decision. The tests prove the garment is fit for the cleanroom. The records prove it to an auditor.

Why Indonesian customers ask for more than a clean-looking garment

Your customers answer to different authorities, and each passes pressure down to you.

  • Pharmaceutical manufacturers work under CPOB (Cara Pembuatan Obat yang Baik), Indonesia’s GMP framework, overseen by BPOM, the national food and drug authority. BPOM is a PIC/S Participating Authority, listed with accession in July 2012, so inspectors read GMP through a framework shared with many other countries. WHO’s GMP main principles (TRS 986, Annex 2) are another widely used reference.
  • Medical-device makers are regulated by the Ministry of Health. Their quality systems expect controlled cleanroom clothing, even though the rules differ from drug GMP.
  • Cosmetics and food producers answer to BPOM as well, usually with lighter cleanroom needs.
  • Electronics and semiconductor plants, including export-oriented factories in industrial zones, care mostly about particles and static, and often audit against their own corporate standards.

A laundry rarely holds a BPOM licence for the garments themselves. But your customer’s CPOB inspection can reach you, because garments are part of their contamination control. If you cannot show how a garment was tested and released, the customer has a gap in its own file.

What gets tested, and why

CheckWhat it tells the customerWho usually asks
Particle countHow many particles the garment sheds when handled or flexedPharma, devices, electronics
ESD propertiesWhether the garment controls static as specifiedElectronics, some device work
MoistureWhether garments are dried properly before packingAlmost everyone
Bioburden / sterility-related checksMicrobial status of garments for aseptic or sterilised supplySterile pharma, devices
Visual and integrity inspectionTears, seam damage, missing parts, labellingEveryone

Particle count

The goal is to know how many particles a garment releases. A commonly used approach is the Helmke drum, which tumbles a garment in a chamber while a particle counter samples the air. Test methods for garment contamination control are covered in IEST-RP-CC003, a non-mandatory recommended practice on garment systems; its current page lists testing in an appendix. The public page does not detail the methods, so buy the current edition to see exactly what it says and which limits apply.

Cleanroom class matters. Air cleanliness is classified under ISO 14644-1 purely by airborne particle concentration, and your customer’s room class drives the garment configuration and acceptance criteria they will ask for. Agree the criteria with each customer in writing rather than assuming.

ESD

Static matters most to electronics customers. The ESD Association maintains the relevant ESD standards, including the ANSI/ESD S20.20 programme standard. Which garment tests apply is a customer and programme decision. Ask what they require, and check the standard text, not a summary.

Moisture

Damp garments are a contamination and microbial-growth risk, and in Indonesia’s humid climate, drying and storage conditions deserve real attention. There is no single universal moisture limit worth quoting here. Set the limit with the customer, measure the same way each time, and record it.

For aseptic and sterile supply, customers want evidence about microbial load or sterilisation status. These checks are usually run by or with a qualified microbiology lab. The laundry’s job is to link the lab result to the exact batch and to make sure nothing ships on a pending result. Methods and limits come from the customer’s specification and the relevant standards, not from the laundry’s own choice.

The records are half the test

Passing results do not help if you cannot find them. An auditor, or your customer’s QA, will usually ask for:

  • Batch traceability: which garments, which wash cycle, which customer, which dates.
  • Result history: every test, who ran it, when, with which equipment.
  • Review and release: a named person who approved the batch, separate from the person who ran the test.
  • Audit trail: what changed in a record, who changed it, and when.
  • Certificates: a document the customer can file with their own batch records.
  • Trends: a drift in particle counts across weeks is easier to fix than a failed batch.
  • Access control: who can enter, edit and approve.

Many Indonesian laundries still run this on paper logbooks and spreadsheets. That can work at small volume. It becomes fragile when customers multiply, results need cross-checking, and a single audit asks for six months of history by batch.

A practical starting checklist

  1. Get each customer’s written specification: room class, tests, limits, certificate format.
  2. Map every test to a method, a reference standard edition, and an instrument with calibration status.
  3. Separate test, review and release into different roles.
  4. Decide what happens to a failed or pending batch, and write it down.
  5. Review trends monthly, not only pass or fail.
  6. Test your retrieval: pick a batch from last quarter and see how fast you can produce its full record.

What software can and cannot do

Software can keep records consistent, enforce who may approve, preserve an audit trail and produce certificates. It cannot make a laundry compliant. Responsibility for GMP-related decisions stays with your quality unit and your customers’ quality units. Any system you adopt should itself be assessed and, where your customers require it, validated within your own quality system.

Talk it through

If you are reviewing how your laundry records tests, releases batches or prepares for customer audits, Teknologia Solutions is happy to have a no-charge conversation about it. We can look at your current process and whether our laundry quality control system would fit. No obligation.


Sources: BPOM regulation portal (JDIH); PIC/S members; WHO TRS 986 Annex 2; IEST-RP-CC003; IEST recommended practices; ISO 14644-1 overview; ESD Association standards. This article is general information. Test methods, limits and regulatory requirements are defined in the current editions of the standards and in current Indonesian regulations; verify against primary sources and your customers’ specifications.